DFS SERIES · BLOWER ACCESSORIES

Inline Air Filters

DFS Series inline air filters help capture particles in the suction lines of vacuum pumps, blowers, compressors and pneumatic conveying systems. The paper filter element and clip-secured housing simplify maintenance and cleaning. Operating temperature range: -15 °F (-26 °C) to 220 °F (104 °C).

Model Range
DFS 020-DFS 400
Connection Range
3/4″ to 4″
Filtration
1 micron
Vacuum Rating
1×10⁻³ mmHg (1.3×10⁻³ mbar)
Temperature Range
-15 °F (-26 °C) to 220 °F (104 °C)
DFS 020-DFS 400 · INSTALLATION & DIMENSIONS

Installation drawing and complete dimensions

Use the drawing and dimensional table together to select the required connection size and confirm the preliminary installation envelope.

DFS Series inline air filter installation and dimensional drawing
The complete d1-d4 and h1-h4 values are listed in the English datasheet.

Scroll horizontally to review every published dimension.

ModelInlet / Outletd1d2d3d4h1h2h3h4
DFS 0203/4″G3/44010010290436512
DFS 1251 1/4″G1 1/448125145116687714
DFS 1501 1/2″G1 1/25317218816711110016
DFS 2002″G26819421725612911020
DFS 2502 1/2″G2 1/28619421725612911013
DFS 4004″G412326827226314719774

Connection sizes are in inches / G-thread standard; dimensions d2-d4 and h1-h4 are in millimetres.

01

Deep Vacuum Ready

Vacuum rating of 1×10⁻³ mmHg (1.3×10⁻³ mbar) for deep-vacuum applications.

02

1-Micron Filtration

The paper element provides 1-micron particle retention with high dust-holding capacity and straightforward cleaning.

03

Durable & Leak-Tight

Steel construction, stainless-steel lid clips and a leak-tight housing support reliable service access.